This machine is quite different
in tablet's conveyance mechanism from conventional machines. With
conventional
machines, an inspector had to change the tablet's direction in order
to inspect the tablet's surface/reverse/side, which often led
to the occurrence of troubles. With this machine, the inspector needs
no change of tablet's direction.
|
|
>Inspection of all the investigational
new drugs manufactured in tablet's research.
> Sampling inspection in manufacturing process.
> Usable as tablet's manufacturing machine in surface/reverse inspection.
(Capacity: 30,000 to 60,000 pieces of tablet / hour)
|
|
|
This machine conveys tablets on conveyor belt,
keeping them in an upright position. It inspects the tablet's surface/reverse
with the CCD two-dimensional cameras placed on both right and left
side. Then it turns tablets by 360 degree on conveyor belt
with a sub-motor, inspecting the tablet's side completely with the
camera placed in the upper part, and then eliminating the defective
tablets at designated position. |
|
|
|
With conventional machines,
an inspector has to change the tablet's direction in order
to inspect the tablet's surface/reverse/side, which often
leads to the occurrence of troubles, and its mechanism is complicated
with many parts, which leads to the higher cost of machine. |
|
|
This new
machine needs no change of tablet's direction. |
|
|
|
With conventional machines,
an inspector has to change the parts whenever the inspection
item (tablet's size) is changed. This leads to the need for
labor and technique as well as for exclusive parts. |
|
|
This new
machine needs no change of parts for the tablet of 6.0 to 9.0
mm in size. |
|
|
|
With conventional machines,
an inspector needs technique and experience in adjusting each
of picture managing equipment, a camera and illumination. |
|
|
This new
machine needs no technique and experience,
because the same
CCD two-dimensional camera and LED illumination as for
"Powder
Inspection Equipment (PIE-C2)" is used. |
|
|
The whole
of tablet's conveyance section can be attached/detached easily,
being washed, which leads to preventing contamination from
occurring. |
|
|
|
Inspection precision |
Analysis capability:
20 micron,
Detection capability: 40 micron |
Inspection
capacity |
For laboratory,
5,000 pieces of tablet / hour
For production, 50,000 pieces of tablet / hour |
Suitable
tablet |
Simple tablet,
Film-coated tablet
(Round shape, 6.0 to 9.0 mm in diameter) |
Incidental
equipment |
|
The foreign material can be fixed in size, being eliminated. |
|
The inspection conditions can be printed out. |
|
The maximum 60 items can be registered. |
|
The inspection conditions of tablet can be instantly
fixed only through the selection of inspection item. |
|
Main
body |
800 mm
(width) 500
mm (depth) 1,840
mm (height) |
|
|
For more information, please contact
Pharmaceutical Materials and Additives Team at the following office:
Osaka Head Office |
|
TEL: +81-6-6203-1891 |
|
FAX: +81-6-6227-0612 |
Tokyo Branch Office |
TEL: +81-3-3866-1141 |
FAX: +81-3-3866-1480 |
Nagoya Branch Office |
TEL: +81-52-957-2223 |
FAX: +81-52-957-2229 |
|
|